ARROW BOARDS · POWER-TILT TRUCK-MOUNTED ARROW BOARDS
INTEGRATED 25-LIGHT POWER-TILT · IN-CAB ELECTRIC DEPLOYMENT

25-Light Power-Tilt Truck-Mounted Arrow Board

Home › Products › Arrow Boards › HK-AB-VP25

A 25-light power-tilt truck-mounted arrow board with a US-reference 96 × 48 in panel, 25 amber PAR 46 lamps and 12 selectable display modes; configured for the quoted destination market.

Who should choose it: Choose the VP25 when the board must travel horizontally and deploy vertically from the cab on a named vehicle. Choose the VF25 when the board can stay upright, or the TF25 / TM25 when the display must be deployed independently of a work truck.

Arrow BoardsTraffic arrow sign Trailer Mounted Arrow BoardsSolar Assist Arrow Board TrailerSolar Arrow Board TrailerMovable Solar Vertical Mast Arrow Boards
PRODUCT OVERVIEW

25-Light Power-Tilt Truck-Mounted Arrow Board

Model HK-AB-VP25 · 25-Light · 90° electric power-tilt

Destination-market configurationConfiguration-specific documentation25-light array · 12 modes

Display panelLED configurationDisplay modesDeploymentPower system
US reference 96 × 48 inOther markets use the quoted regional panel.25 amber LED lampsPAR 46 · 5.75 in (146 mm) US reference.12 selectable modesFull directional, chevron and caution pattern set.90° electric power-tiltEngineered for the named vehicle interface.12 V DC vehicle supplyAuxiliary battery and solar maintainer optional.
The HK-AB-VP25 suits mobile maintenance, road striping, sweeping, pothole repair, convoy and TMA operations. Its 90° power-tilt frame lowers the display for travel, then deploys it vertically from the cab where route height and frequent movement make powered stowage valuable.
— Selection

Choose by site requirement, not by the label alone

This page covers one defined HANKUN model. Panel layout, regional requirements and evidence status remain configuration-specific; a different lamp count or regulatory layout is routed to the correct model instead of being hidden under one global claim.
HK-AB-VP25 25-light power-tilt arrow board lowered to the horizontal travel position on a work truck
01

Choose VP25

You need a horizontal travel position and electric in-cab deployment.
HK-AB-VF25 25-light fixed upright arrow board on a vehicle rack
02

Choose VF25

You can carry the board upright and prefer the fewest moving parts.
HK-AB-TF25 / TM25 25-light arrow board trailer standing on its legs
03

Choose TF25 / TM25

The board must be deployed independently of a work truck.
— Markets

Destination-market configurations

“Available” means HANKUN can quote the named configuration. It does not mean every unit under this model number is automatically approved in every jurisdiction.
MarketBuyer terminologyConfiguration boundaryReferenceStatus
United StatesArrow Board / Type C Arrow Board96 × 48 in minimum Type C class; 15-element MUTCD minimum; HANKUN array as stated by modelMUTCD 11th Edition with Revision 1, Section 6L.06 and Figure 6L-3Configuration available. Conformity is stated only for the quoted SKU and evidence package.
Canada / OntarioMTO Arrow Board / Ontario Arrow BoardA separate Ontario-specific lamp, panel and failsafe configurationCurrent project clause and MTO requirementsNot represented by this 25-light SKU unless the quotation names a dedicated configuration.
AustraliaDirectional Arrow Board / Illuminated Flashing Arrow SignAustralian-specific panel size and lamp layout; do not substitute the US 25-light faceAS 4192:2022 plus state authority requirementsSeparate regional configuration required.
New ZealandHorizontal Arrow Board / Light Arrow System25-light project configuration; active area, lamp performance, rear panel and in-cab indication set by the tenderCurrent NZGTTM, RCA and project requirementsProject review required before a compliance statement is issued.

Compliance boundary: Supporting documents apply only to the SKU, regional configuration and BOM revision stated in the quotation. HANKUN does not use one global badge to imply that a US, Ontario, Australian and New Zealand build are physically identical.

— Mechanism

What is different about VP25?

The mechanism is the purchasing difference. The lamp array and controller must still be matched to the market, but the deployment method determines transport height, installation, inspection and field operation.

90° power-tilt frame

Moves between horizontal travel and vertical operating positions with an electric actuator.

In-cab deployment

The operator raises, lowers and selects modes without standing beside live traffic.

Twelve display modes

Provides the full 25-light pattern set.

Engineered vehicle interface

Mounting loads, current draw and travelling height are checked against the named truck.

Mechanism and interface

ItemHK-AB-VP25Condition / evidence
Deployment motion90° electric power-tiltHorizontal travel position to vertical operating position
ActuatorConfiguration-specific electric linear actuatorLoad, stroke, ingress protection and duty cycle named in the installation sheet
ControlIn-cab raise / lower and display-mode controlHarness length and controller location set by order
Operating retentionPositive mechanical or validated actuator retentionExact arrangement shown on the mounting drawing
Manual recoveryProvided where specifiedProcedure depends on the selected actuator and mount
Vehicle interfaceBolted engineered mounting framePayload, rear-axle load and fastener torque checked before release
Travel heightVehicle-specificShown on the GA drawing; never described as below cab height without measurement
— Display modes

12 display modes for the 25-light controller

The controller groups its patterns under the operating categories required by MUTCD Section 6L.06. Pattern availability does not authorize a traffic operation; the permitted mode is determined by the road authority and traffic-management plan.
Flashing Arrow — Left
Flashing Arrow — Right
Sequencing Arrow — Left
Sequencing Arrow — Right
Flashing Double Arrow
Flashing Caution Bar
Four-Corner Caution
Sequencing Chevron — Left
Sequencing Chevron — Right
Arrow Head Moving — Left
Arrow Head Moving — Right
Alternating Double Diamond
Current US reference: MUTCD 11th Edition with Revision 1, Section 6L.06 and Figure 6L-3. Quotation documents must identify the governing edition and jurisdiction.
— Technical

Technical specifications

Reference values describe the standard configuration basis. Contract values are the figures shown on the quotation, GA drawing, installation sheet and serial-numbered inspection record.
SpecificationValueCondition / evidence
ModelHK-AB-VP25Product-family identifier; regional configuration is stated separately
Mounting / deployment90° electric power-tiltSee mechanism table above
Reference US panel96 × 48 in (2438 × 1219 mm)MUTCD Type C minimum-size class
Display faceSingle face standardDouble face requires a separate configuration and power review
LED lamps25 per faceLamp count is per display face
Reference US lamp headPAR 46 amber/yellow LED · 5.75 in (146 mm) nominalActual photometric report and part number tied to ordered SKU
Display modes12Mode availability does not replace the traffic-management plan
US flash rate25–40 flashes per minuteMUTCD 11th Edition with Revision 1, Section 6L.06
DimmingAutomatic photocell dimming + manual overrideNighttime setting validated with ordered controller and lamp
US legibility requirement1 mi (1.6 km) for Type CRequirement from Figure 6L-3; product performance must be supported by the submittal
StructureWelded structural-steel frame; reinforced aluminium display panelSection sizes and finish named on the drawing
Operating weightPanel and mount mass declared on the installation sheet and checked against vehicle payload and rear-axle ratingNever apply a reference weight to a different BOM
Warranty3 years, subject to written quotation termsCoverage, exclusions and start date stated in the commercial offer
Nominal system voltage12 V DCOther vehicle voltages available by quotation
Primary supplyVehicle electrical systemDedicated fused circuit with reverse-polarity protection
Low-voltage protectionStandardSet to protect vehicle starting capacity
Auxiliary batteryOptionalCapacity and reserve stated for the ordered duty cycle
Solar maintainerOptionalUsed where long engine-off operation is required
Current drawConfiguration-specificMeasured value shown on the installation sheet
— Quality evidence

Manufacturing and quality evidence chain

Equipment photographs show capability; controlled records show what was built. HANKUN ties design, production, testing and shipment evidence to the ordered configuration and finished unit.
Engineer releasing the order against the approved drawing and BOM
01

Controlled release

The order is released against an approved drawing and BOM revision.
Incoming inspection of lamp heads, controller, battery and solar module by lot
02

Incoming inspection

Lamp heads, controller, battery, solar module and structural material are checked by lot.
Fabrication bay: cutting, forming and welding checked against the released drawing
03

Fabrication record

Cutting, forming, welding, fit-up and coating checks follow the released drawing.
Electrical test of a 25-light panel: display modes, flash rate, dimming and charge control
04

Electrical test

Every unit receives display-mode, flash-rate, dimming, charging, protection and control checks.
Configuration validation: panel and mount mass weighed for the finished build
05

Configuration validation

Weight, dimensions and mechanism-specific values are recorded for the finished build.
Serial-number dossier: final inspection, photographs, documents and packing record
06

Serial-number dossier

The final inspection, photos, documents and packing record are tied to the unit serial number.
— Documents

Configuration documents

Files are provided by stage so the buyer knows what is available with the quotation, before production and with shipment. Download buttons should be connected only after the approved file exists.
DocumentWhen suppliedScope
Configuration datasheetWith quotationValues apply to the quoted SKU and BOM revision.
General arrangement drawingBefore production releaseOverall, operating, transport and mounting dimensions.
Display-mode and lamp-position diagramWith orderMatches the ordered controller programme.
User manual and wiring diagramWith shipmentConfiguration-specific operating and service instructions.
Factory inspection and weight recordWith shipmentReferenced to the unit serial number.
Third-party reports / listingsWhere requiredNamed issuing body, report number, issue date and applicable SKU.
— FAQ

Frequently asked questions

Why is this called power-tilt?

Power-tilt is the established North American mounting term for an electric actuator rotating the frame through 90 degrees between travel and operating positions.

Can it fit any truck?

No universal fit is claimed. The quotation requires the vehicle make, model, bed or carrier details, payload, rear-axle rating, supply voltage and permitted travelling height.

Can the board run with the engine off?

Yes when the ordered vehicle electrical system supports the duty cycle or when an auxiliary battery and charging option are fitted. The installation sheet states the measured draw and reserve.

What information is needed for an accurate quotation?

Send the country, state or province, road authority, tender clause, mounting or operation type, lamp count, face count, power source, quantity, destination port and required submittal documents.

How is the warranty stated?

The commercial quotation states the three-year warranty scope, covered components, exclusions, start date and claim process. The page does not replace those written terms.

Related Products for Your Traffic Safety Solutions

North America Local After-Sales

Canada

US

Canada, Monte

Become a Distributor

Get a Traffic Safety Quote

Design a Solar Traffic Solution

Drag & Drop Files, Choose Files to Upload

Get Technical Proposal

Drag & Drop Files, Choose Files to Upload
Max. File Size: 100 MB

Video Consultation

Fill in your information to reserve a free exclusive video consultation. Our team will contact you within 24 hours to arrange a dedicated online meeting.